probe: Move multi-sampling capability from ProbePointsHelper to Probe
This changes the config file so that the configuration of multi-samples is now done in the [probe] (and [bltouch]) section instead of the various delta, bed_mesh, z_tilt, etc. config sections. With this change, PROBE and PROBE_CALIBRATE commands now also utilize multi-sampling. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
committed by
KevinOConnor
parent
5989f7a8a6
commit
2b8dca5dbf
@@ -158,6 +158,10 @@ x_offset: 0.0
|
||||
y_offset: 25.0
|
||||
z_offset: 0.00
|
||||
speed: 2.0
|
||||
samples: 4
|
||||
# Number of times to probe a point
|
||||
sample_retract_dist: 6.0
|
||||
# How far to retract (in mm) from the probe point for multi-probe samples
|
||||
|
||||
[fan]
|
||||
# Print cooling fan
|
||||
@@ -231,10 +235,6 @@ points:
|
||||
# Probe points
|
||||
speed: 200
|
||||
horizontal_move_z: 6
|
||||
samples: 4
|
||||
# Number of times to probe a point
|
||||
sample_retract_dist: 6.0
|
||||
# How far to retract (in mm) from the probe point for multi-probe samples
|
||||
|
||||
[display]
|
||||