heaters: Remove deprecated thermistor "NTC 100K beta 3950"
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
@@ -102,12 +102,6 @@ temperature1: 25
|
||||
resistance1: 100000
|
||||
beta: 3974
|
||||
|
||||
# Definition inherent from name. This sensor is deprecated!
|
||||
[thermistor NTC 100K beta 3950]
|
||||
temperature1: 25
|
||||
resistance1: 100000
|
||||
beta: 3950
|
||||
|
||||
# Definition from description of Marlin "thermistor 75"
|
||||
[thermistor NTC 100K MGB18-104F39050L32]
|
||||
temperature1: 25
|
||||
|
||||
Reference in New Issue