mirror of
git://soft.sys114.com/klipper
synced 2026-02-11 13:20:25 +09:00
temperature_sensors: Deprecate "NTC 100K beta 3950" thermistor
It seems the common "beta 3950" thermistors generally follow a temperature table defined by the new "Generic 3950" definition. Using a table that actually follows the "beta 3950" temperature curve is generally less accurate. Deprecate the existing "NTC 100K beta 3950" definition to avoid this common issue. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
@@ -127,7 +127,7 @@ rotation_distance: 29.888
|
||||
nozzle_diameter: 0.400
|
||||
filament_diameter: 1.750
|
||||
heater_pin: PD5
|
||||
sensor_type: NTC 100K beta 3950
|
||||
sensor_type: Generic 3950
|
||||
sensor_pin: PA7
|
||||
control: pid
|
||||
pid_Kp: 18.214030
|
||||
@@ -138,7 +138,7 @@ max_temp: 230
|
||||
|
||||
[heater_bed]
|
||||
heater_pin: PD4
|
||||
sensor_type: NTC 100K beta 3950
|
||||
sensor_type: Generic 3950
|
||||
sensor_pin: PA6
|
||||
control: pid
|
||||
pid_Kp: 71.321
|
||||
|
||||