mirror of
https://github.com/hardkernel/linux.git
synced 2026-06-05 18:41:58 +09:00
Revert "sched/fair: Detect capacity inversion"
This reverts commit 30f04dd56d.
It breaks the Android kernel abi, so revert it. If it needs to come
back later, it can do so in an abi-safe way.
Bug: 161946584
Cc: Qais Yousef <qyousef@google.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@google.com>
Change-Id: I576fa3894406ad6db3d4eafe5c08572d20c71902
This commit is contained in:
@@ -8513,74 +8513,17 @@ static unsigned long scale_rt_capacity(int cpu)
|
|||||||
|
|
||||||
static void update_cpu_capacity(struct sched_domain *sd, int cpu)
|
static void update_cpu_capacity(struct sched_domain *sd, int cpu)
|
||||||
{
|
{
|
||||||
unsigned long capacity_orig = arch_scale_cpu_capacity(cpu);
|
|
||||||
unsigned long capacity = scale_rt_capacity(cpu);
|
unsigned long capacity = scale_rt_capacity(cpu);
|
||||||
struct sched_group *sdg = sd->groups;
|
struct sched_group *sdg = sd->groups;
|
||||||
struct rq *rq = cpu_rq(cpu);
|
|
||||||
|
|
||||||
rq->cpu_capacity_orig = capacity_orig;
|
cpu_rq(cpu)->cpu_capacity_orig = arch_scale_cpu_capacity(cpu);
|
||||||
|
|
||||||
if (!capacity)
|
if (!capacity)
|
||||||
capacity = 1;
|
capacity = 1;
|
||||||
|
|
||||||
trace_android_rvh_update_cpu_capacity(cpu, &capacity);
|
trace_android_rvh_update_cpu_capacity(cpu, &capacity);
|
||||||
rq->cpu_capacity = capacity;
|
cpu_rq(cpu)->cpu_capacity = capacity;
|
||||||
|
trace_sched_cpu_capacity_tp(cpu_rq(cpu));
|
||||||
/*
|
|
||||||
* Detect if the performance domain is in capacity inversion state.
|
|
||||||
*
|
|
||||||
* Capacity inversion happens when another perf domain with equal or
|
|
||||||
* lower capacity_orig_of() ends up having higher capacity than this
|
|
||||||
* domain after subtracting thermal pressure.
|
|
||||||
*
|
|
||||||
* We only take into account thermal pressure in this detection as it's
|
|
||||||
* the only metric that actually results in *real* reduction of
|
|
||||||
* capacity due to performance points (OPPs) being dropped/become
|
|
||||||
* unreachable due to thermal throttling.
|
|
||||||
*
|
|
||||||
* We assume:
|
|
||||||
* * That all cpus in a perf domain have the same capacity_orig
|
|
||||||
* (same uArch).
|
|
||||||
* * Thermal pressure will impact all cpus in this perf domain
|
|
||||||
* equally.
|
|
||||||
*/
|
|
||||||
if (static_branch_unlikely(&sched_asym_cpucapacity)) {
|
|
||||||
unsigned long inv_cap = capacity_orig - thermal_load_avg(rq);
|
|
||||||
struct perf_domain *pd = rcu_dereference(rq->rd->pd);
|
|
||||||
|
|
||||||
rq->cpu_capacity_inverted = 0;
|
|
||||||
|
|
||||||
for (; pd; pd = pd->next) {
|
|
||||||
struct cpumask *pd_span = perf_domain_span(pd);
|
|
||||||
unsigned long pd_cap_orig, pd_cap;
|
|
||||||
|
|
||||||
cpu = cpumask_any(pd_span);
|
|
||||||
pd_cap_orig = arch_scale_cpu_capacity(cpu);
|
|
||||||
|
|
||||||
if (capacity_orig < pd_cap_orig)
|
|
||||||
continue;
|
|
||||||
|
|
||||||
/*
|
|
||||||
* handle the case of multiple perf domains have the
|
|
||||||
* same capacity_orig but one of them is under higher
|
|
||||||
* thermal pressure. We record it as capacity
|
|
||||||
* inversion.
|
|
||||||
*/
|
|
||||||
if (capacity_orig == pd_cap_orig) {
|
|
||||||
pd_cap = pd_cap_orig - thermal_load_avg(cpu_rq(cpu));
|
|
||||||
|
|
||||||
if (pd_cap > inv_cap) {
|
|
||||||
rq->cpu_capacity_inverted = inv_cap;
|
|
||||||
break;
|
|
||||||
}
|
|
||||||
} else if (pd_cap_orig > inv_cap) {
|
|
||||||
rq->cpu_capacity_inverted = inv_cap;
|
|
||||||
break;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
trace_sched_cpu_capacity_tp(rq);
|
|
||||||
|
|
||||||
sdg->sgc->capacity = capacity;
|
sdg->sgc->capacity = capacity;
|
||||||
sdg->sgc->min_capacity = capacity;
|
sdg->sgc->min_capacity = capacity;
|
||||||
|
|||||||
@@ -993,7 +993,6 @@ struct rq {
|
|||||||
|
|
||||||
unsigned long cpu_capacity;
|
unsigned long cpu_capacity;
|
||||||
unsigned long cpu_capacity_orig;
|
unsigned long cpu_capacity_orig;
|
||||||
unsigned long cpu_capacity_inverted;
|
|
||||||
|
|
||||||
struct callback_head *balance_callback;
|
struct callback_head *balance_callback;
|
||||||
|
|
||||||
@@ -2625,24 +2624,6 @@ static inline unsigned long capacity_orig_of(int cpu)
|
|||||||
{
|
{
|
||||||
return cpu_rq(cpu)->cpu_capacity_orig;
|
return cpu_rq(cpu)->cpu_capacity_orig;
|
||||||
}
|
}
|
||||||
|
|
||||||
/*
|
|
||||||
* Returns inverted capacity if the CPU is in capacity inversion state.
|
|
||||||
* 0 otherwise.
|
|
||||||
*
|
|
||||||
* Capacity inversion detection only considers thermal impact where actual
|
|
||||||
* performance points (OPPs) gets dropped.
|
|
||||||
*
|
|
||||||
* Capacity inversion state happens when another performance domain that has
|
|
||||||
* equal or lower capacity_orig_of() becomes effectively larger than the perf
|
|
||||||
* domain this CPU belongs to due to thermal pressure throttling it hard.
|
|
||||||
*
|
|
||||||
* See comment in update_cpu_capacity().
|
|
||||||
*/
|
|
||||||
static inline unsigned long cpu_in_capacity_inversion(int cpu)
|
|
||||||
{
|
|
||||||
return cpu_rq(cpu)->cpu_capacity_inverted;
|
|
||||||
}
|
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
/**
|
/**
|
||||||
|
|||||||
Reference in New Issue
Block a user