arm64: dts: rockchip: update thermal config and add gpu's parameters for rk3368
add both static and dynamic power coefficient for gpu module, and add gpu as a cooling device in the thermal zone. rename the thermal zone's config and make it more readable. update temperature pooling interval and make the temperature control more effective. Change-Id: I6e0939fe26ece9c611151ffbbb55e62b824a602f Signed-off-by: Rocky Hao <rocky.hao@rock-chips.com>
This commit is contained in:
@@ -600,26 +600,26 @@
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
thermal-zones {
|
||||
cpu {
|
||||
polling-delay-passive = <300>; /* milliseconds */
|
||||
polling-delay = <300>; /* milliseconds */
|
||||
thermal_zones: thermal-zones {
|
||||
soc_thermal: soc-thermal {
|
||||
polling-delay-passive = <200>; /* milliseconds */
|
||||
polling-delay = <200>; /* milliseconds */
|
||||
sustainable-power = <600>; /* milliwatts */
|
||||
|
||||
thermal-sensors = <&tsadc 0>;
|
||||
trips {
|
||||
cpu_alert0: cpu_alert0 {
|
||||
threshold: trip-point@0 {
|
||||
temperature = <70000>; /* millicelsius */
|
||||
hysteresis = <2000>; /* millicelsius */
|
||||
type = "passive";
|
||||
};
|
||||
cpu_alert1: cpu_alert1 {
|
||||
target: trip-point@1 {
|
||||
temperature = <80000>; /* millicelsius */
|
||||
hysteresis = <2000>; /* millicelsius */
|
||||
type = "passive";
|
||||
};
|
||||
cpu_crit: cpu_crit {
|
||||
temperature = <90000>; /* millicelsius */
|
||||
soc_crit: soc-crit {
|
||||
temperature = <95000>; /* millicelsius */
|
||||
hysteresis = <2000>; /* millicelsius */
|
||||
type = "critical";
|
||||
};
|
||||
@@ -627,23 +627,29 @@
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert1>;
|
||||
trip = <&target>;
|
||||
cooling-device =
|
||||
<&cpu_l0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
contribution = <1024>;
|
||||
};
|
||||
map1 {
|
||||
trip = <&cpu_alert1>;
|
||||
trip = <&target>;
|
||||
cooling-device =
|
||||
<&cpu_b0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
contribution = <1024>;
|
||||
};
|
||||
map2 {
|
||||
trip = <&target>;
|
||||
cooling-device =
|
||||
<&gpu THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
contribution = <1024>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
gpu_thermal: gpu-thermal {
|
||||
polling-delay-passive = <300>; /* milliseconds */
|
||||
polling-delay = <300>; /* milliseconds */
|
||||
polling-delay-passive = <200>; /* milliseconds */
|
||||
polling-delay = <200>; /* milliseconds */
|
||||
thermal-sensors = <&tsadc 1>;
|
||||
};
|
||||
};
|
||||
@@ -1348,6 +1354,16 @@
|
||||
interrupt-names = "rogue-g6110-irq";
|
||||
power-domains = <&power RK3368_PD_GPU_1>;
|
||||
operating-points-v2 = <&gpu_opp_table>;
|
||||
#cooling-cells = <2>; /* min followed by max */
|
||||
gpu_power_model: power_model {
|
||||
compatible = "arm,mali-simple-power-model";
|
||||
voltage = <900>;
|
||||
frequency = <500>;
|
||||
static-power = <300>;
|
||||
dynamic-power = <396>;
|
||||
ts = <32000 4700 (-80) 2>;
|
||||
thermal-zone = "gpu-thermal";
|
||||
};
|
||||
};
|
||||
|
||||
gpu_opp_table: gpu_opp_table {
|
||||
|
||||
Reference in New Issue