Files
linux/drivers
Maciej Purski a28caa7b8f iio: adc: ina2xx: Make calibration register value fixed
Calibration register is used for calculating current register in
hardware according to datasheet:
current = shunt_volt * calib_register / 2048 (ina 226)
current = shunt_volt * calib_register / 4096 (ina 219)

Fix calib_register value to 2048 for ina226 and 4096 for ina 219 in
order to avoid truncation error and provide best precision allowed
by shunt_voltage measurement. Make current scale value follow changes
of shunt_resistor from sysfs as calib_register value is now fixed.

Power_lsb value should also follow shunt_resistor changes as stated in
datasheet:
power_lsb = 25 * current_lsb (ina 226)
power_lsb = 20 * current_lsb (ina 219)

This is a part of the patchset: https://lkml.org/lkml/2017/11/22/394

Signed-off-by: Maciej Purski <m.purski@samsung.com>
Reviewed-by:  Stefan Brüns <stefan.bruens@rwth-aachen.de>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2018-01-08 16:03:42 +01:00
..
2017-12-20 13:16:33 -07:00
2017-11-13 01:34:14 +01:00
2017-12-18 09:16:35 +01:00
2017-12-18 13:55:43 -07:00
2017-12-02 21:31:03 -05:00
2017-12-14 21:01:40 +02:00