Files
linux/drivers
Riwen Lu 35b651d6bd hwmon: (scpi-hwmon) shows the negative temperature properly
[ Upstream commit 78d1355234 ]

The scpi hwmon shows the sub-zero temperature in an unsigned integer,
which would confuse the users when the machine works in low temperature
environment. This shows the sub-zero temperature in an signed value and
users can get it properly from sensors.

Signed-off-by: Riwen Lu <luriwen@kylinos.cn>
Tested-by: Xin Chen <chenxin@kylinos.cn>
Link: https://lore.kernel.org/r/20210604030959.736379-1-luriwen@kylinos.cn
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
2021-06-23 14:41:27 +02:00
..
2021-05-14 09:44:24 +02:00
2020-12-30 11:51:26 +01:00
2021-04-07 14:47:39 +02:00