Vasanthakumar Thiagarajan ee9ca147c5 ath10k: Fix survey reporting with QCA4019
In QCA4019, cycle counter wraparound in same fashion
as QCA988X. When the cycle counter wraparound it
resets to 0x7fffffff. Set has_shifted_cc_wraparound to
true for QCA4019 to enable the code path to handle cycle
counter wraparound for consistent survey report.

Signed-off-by: Vasanthakumar Thiagarajan <vthiagar@qti.qualcomm.com>