mirror of
git://soft.sys114.com/klipper
synced 2026-02-10 17:38:07 +09:00
Make sure the ADC range sent to the MCU can be encoded into a 16bit integer. Otherwise, if the provided min_temp/max_temp was outside the range of possible values it could result in a spurious mcu shutdown. In particular, the AD595 could not properly encode a min_temp of zero. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>