mirror of
https://github.com/hardkernel/linux.git
synced 2026-06-07 19:30:30 +09:00
USB: serial: keyspan: fix use-after-free in probe error path
commit35be1a71d7upstream. The interface instat and indat URBs were submitted in attach, but never unlinked in release before deallocating the corresponding transfer buffers. In the case of a late probe error (e.g. due to failed minor allocation), disconnect would not have been called before release, causing the buffers to be freed while the URBs are still in use. We'd also end up with active URBs for an unbound interface. Fixes:f9c99bb8b3("USB: usb-serial: replace shutdown with disconnect, release") Signed-off-by: Johan Hovold <johan@kernel.org> Acked-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
c0b572be50
commit
00efa6c22d
@@ -2376,6 +2376,10 @@ static void keyspan_release(struct usb_serial *serial)
|
||||
|
||||
s_priv = usb_get_serial_data(serial);
|
||||
|
||||
/* Make sure to unlink the URBs submitted in attach. */
|
||||
usb_kill_urb(s_priv->instat_urb);
|
||||
usb_kill_urb(s_priv->indat_urb);
|
||||
|
||||
usb_free_urb(s_priv->instat_urb);
|
||||
usb_free_urb(s_priv->indat_urb);
|
||||
usb_free_urb(s_priv->glocont_urb);
|
||||
|
||||
Reference in New Issue
Block a user