scsi: lpfc: Reinitialize an NPIV's VMID data structures after FDISC

[ Upstream commit 8dc8eb89f4df74593ba4bf30c3d31a0fc6d3ea47 ]

After a follow up FDISC cmpl, an NPIV's VMID data structures are not
updated.

Fix by calling lpfc_reinit_vmid and copying the physical port's vmid_flag
to the NPIV's vmid_flag in the NPIV registration cmpl code path.

Signed-off-by: Justin Tee <justin.tee@broadcom.com>
Link: https://lore.kernel.org/r/20231207224039.35466-3-justintee8345@gmail.com
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
Justin Tee
2023-12-07 14:40:37 -08:00
committed by Greg Kroah-Hartman
parent 40ac9c17b6
commit 6d38434f42

View File

@@ -11110,6 +11110,14 @@ mbox_err_exit:
lpfc_nlp_put(ndlp);
mempool_free(pmb, phba->mbox_mem_pool);
/* reinitialize the VMID datastructure before returning.
* this is specifically for vport
*/
if (lpfc_is_vmid_enabled(phba))
lpfc_reinit_vmid(vport);
vport->vmid_flag = vport->phba->pport->vmid_flag;
return;
}