platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table
[ Upstream commitd6423bd030] There are several Beckhoff Automation industrial PC boards which use pmc_plt_clk* clocks for ethernet controllers. This adds affected boards to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and not turned off. Fixes:648e921888("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
4e2ec4a370
commit
a415e2db35
@@ -443,6 +443,30 @@ static const struct dmi_system_id critclk_systems[] = {
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB3163",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB6263",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB6363",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
|
||||
},
|
||||
},
|
||||
{ /*sentinel*/ }
|
||||
};
|
||||
|
||||
|
||||