arm64: dts: hi3660: Add missing cooling device properties for CPUs
The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Wei Xu <xuwei5@hisilicon.com>
This commit is contained in:
@@ -79,6 +79,7 @@
|
||||
capacity-dmips-mhz = <592>;
|
||||
clocks = <&stub_clock HI3660_CLK_STUB_CLUSTER0>;
|
||||
operating-points-v2 = <&cluster0_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu2: cpu@2 {
|
||||
@@ -91,6 +92,7 @@
|
||||
capacity-dmips-mhz = <592>;
|
||||
clocks = <&stub_clock HI3660_CLK_STUB_CLUSTER0>;
|
||||
operating-points-v2 = <&cluster0_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu3: cpu@3 {
|
||||
@@ -103,6 +105,7 @@
|
||||
capacity-dmips-mhz = <592>;
|
||||
clocks = <&stub_clock HI3660_CLK_STUB_CLUSTER0>;
|
||||
operating-points-v2 = <&cluster0_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu4: cpu@100 {
|
||||
@@ -129,6 +132,7 @@
|
||||
capacity-dmips-mhz = <1024>;
|
||||
clocks = <&stub_clock HI3660_CLK_STUB_CLUSTER1>;
|
||||
operating-points-v2 = <&cluster1_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu6: cpu@102 {
|
||||
@@ -141,6 +145,7 @@
|
||||
capacity-dmips-mhz = <1024>;
|
||||
clocks = <&stub_clock HI3660_CLK_STUB_CLUSTER1>;
|
||||
operating-points-v2 = <&cluster1_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu7: cpu@103 {
|
||||
@@ -153,6 +158,7 @@
|
||||
capacity-dmips-mhz = <1024>;
|
||||
clocks = <&stub_clock HI3660_CLK_STUB_CLUSTER1>;
|
||||
operating-points-v2 = <&cluster1_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||