UPSTREAM: iio: light: vl6180: Correct ALS scale for non-default gain/integration time

The reported scale was only correct for the default settings of 100 ms
integration time and gain 1.

This aligns the reported scale with the behaviour of any other IIO driver
and the documented ABI, but may require userspace changes if someone uses
non-default settings.

Change-Id: I969d50d317f20d05d26db74d497dba790b5a7c25
Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Ziyuan Xu <xzy.xu@rock-chips.com>
(cherry picked from commit 3525d7cfb7)
This commit is contained in:
Stefan Brüns
2017-09-24 23:59:20 +02:00
committed by Ziyuan Xu
parent 990f320ea5
commit ade6b9cc4e

View File

@@ -315,9 +315,12 @@ static int vl6180_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_SCALE:
switch (chan->type) {
case IIO_LIGHT:
*val = 0; /* one ALS count is 0.32 Lux */
*val2 = 320000;
break;
/* one ALS count is 0.32 Lux @ gain 1, IT 100 ms */
*val = 32000; /* 0.32 * 1000 * 100 */
*val2 = data->als_gain_milli * data->als_it_ms;
return IIO_VAL_FRACTIONAL;
case IIO_DISTANCE:
*val = 0; /* sensor reports mm, scale to meter */
*val2 = 1000;