hv_netvsc: Use Windows version instead of NVSP version on GPAD teardown
commit 2afc5d61a7197de25a61f54ea4ecfb4cb62b1d42A upstram When changing network interface settings, Windows guests older than WS2016 can no longer shutdown. This was addressed by commit0ef58b0a05("hv_netvsc: change GPAD teardown order on older versions"), however the issue also occurs on WS2012 guests that share NVSP protocol versions with WS2016 guests. Hence we use Windows version directly to differentiate them. Fixes:0ef58b0a05("hv_netvsc: change GPAD teardown order on older versions") Signed-off-by: Mohammed Gamal <mgamal@redhat.com> Signed-off-by: David S. Miller <davem@davemloft.net> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
be9c798d0d
commit
d8c3e04d39
@@ -569,13 +569,13 @@ void netvsc_device_remove(struct hv_device *device)
|
||||
netdev_dbg(ndev, "net device safe to remove\n");
|
||||
|
||||
/* older versions require that buffer be revoked before close */
|
||||
if (net_device->nvsp_version < NVSP_PROTOCOL_VERSION_4)
|
||||
if (vmbus_proto_version < VERSION_WIN10)
|
||||
netvsc_teardown_gpadl(device, net_device);
|
||||
|
||||
/* Now, we can close the channel safely */
|
||||
vmbus_close(device->channel);
|
||||
|
||||
if (net_device->nvsp_version >= NVSP_PROTOCOL_VERSION_4)
|
||||
if (vmbus_proto_version >= VERSION_WIN10)
|
||||
netvsc_teardown_gpadl(device, net_device);
|
||||
|
||||
/* Release all resources */
|
||||
|
||||
Reference in New Issue