power: supply: bq24190_charger: Fix irq trigger to IRQF_TRIGGER_FALLING
commit767eee362fupstream. The interrupt signal is TRIGGER_FALLING. This is is specified in the data sheet PIN FUNCTIONS: "The INT pin sends active low, 256us pulse to host to report charger device status and fault." Also the direction can be seen in the data sheet Figure 37 "BQ24190 with D+/D- Detection and USB On-The-Go (OTG)" which shows a 10k pull-up resistor installed for the sample configurations. Fixes:d7bf353fd0("bq24190_charger: Add support for TI BQ24190 Battery Charger") Signed-off-by: Liam Breck <kernel@networkimprov.net> Acked-by: Mark Greer <mgreer@animalcreek.com> Acked-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Sebastian Reichel <sre@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
89e8bd3add
commit
d8d6aedd54
@@ -1394,7 +1394,7 @@ static int bq24190_probe(struct i2c_client *client,
|
||||
|
||||
ret = devm_request_threaded_irq(dev, bdi->irq, NULL,
|
||||
bq24190_irq_handler_thread,
|
||||
IRQF_TRIGGER_RISING | IRQF_ONESHOT,
|
||||
IRQF_TRIGGER_FALLING | IRQF_ONESHOT,
|
||||
"bq24190-charger", bdi);
|
||||
if (ret < 0) {
|
||||
dev_err(dev, "Can't set up irq handler\n");
|
||||
|
||||