UPSTREAM: regulator: pwm: Document pwm-dutycycle-unit and pwm-dutycycle-range

Document the pwm-dutycycle-unit and pwm-dutycycle-range properties.

Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Acked-by: Brian Norris <briannorris@chromium.org>
Acked-by: Rob Herring <robh@kernel.org>
Acked-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
(cherry picked from commit 58fd822b2e)

Change-Id: I029307b54210f2203276a467e947d0fa2e51966d
Signed-off-by: David Wu <david.wu@rock-chips.com>
This commit is contained in:
Boris Brezillon
2016-06-14 11:13:22 +02:00
committed by Huang, Tao
parent d81d8e4b87
commit e243129c07

View File

@@ -34,6 +34,18 @@ Only required for Voltage Table Mode:
First cell is voltage in microvolts (uV)
Second cell is duty-cycle in percent (%)
Optional properties for Continuous mode:
- pwm-dutycycle-unit: Integer value encoding the duty cycle unit. If not
defined, <100> is assumed, meaning that
pwm-dutycycle-range contains values expressed in
percent.
- pwm-dutycycle-range: Should contain 2 entries. The first entry is encoding
the dutycycle for regulator-min-microvolt and the
second one the dutycycle for regulator-max-microvolt.
Duty cycle values are expressed in pwm-dutycycle-unit.
If not defined, <0 100> is assumed.
NB: To be clear, if voltage-table is provided, then the device will be used
in Voltage Table Mode. If no voltage-table is provided, then the device will
be used in Continuous Voltage Mode.
@@ -53,6 +65,13 @@ Continuous Voltage With Enable GPIO Example:
regulator-min-microvolt = <1016000>;
regulator-max-microvolt = <1114000>;
regulator-name = "vdd_logic";
/* unit == per-mille */
pwm-dutycycle-unit = <1000>;
/*
* Inverted PWM logic, and the duty cycle range is limited
* to 30%-70%.
*/
pwm-dutycycle-range <700 300>; /* */
};
Voltage Table Example: