FROMLIST: thermal: cpu_cooling: Make the power-related code depend on IPA

The core CPU cooling infrastructure has power-related functions
that have only one client: IPA. Since there can be no user of those
functions if IPA is not compiled in, make sure to guard them with
checks on CONFIG_THERMAL_GOV_POWER_ALLOCATOR to not waste space
unnecessarily.

Change-Id: I889c824e1223a3da47d964da01f722fcdf77bd91
Suggested-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Quentin Perret <quentin.perret@arm.com>
Message-Id: <20190530092038.12020-3-quentin.perret@arm.com>
This commit is contained in:
Quentin Perret
2019-05-30 10:20:37 +01:00
parent 3a77694caa
commit e5c4fc9d50

View File

@@ -46,7 +46,9 @@
*/
struct freq_table {
u32 frequency;
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
u32 power;
#endif
};
/**
@@ -96,28 +98,6 @@ static DEFINE_IDA(cpufreq_ida);
static DEFINE_MUTEX(cooling_list_lock);
static LIST_HEAD(cpufreq_cdev_list);
/* Below code defines functions to be used for cpufreq as cooling device */
/**
* get_level: Find the level for a particular frequency
* @cpufreq_cdev: cpufreq_cdev for which the property is required
* @freq: Frequency
*
* Return: level corresponding to the frequency.
*/
static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
unsigned int freq)
{
struct freq_table *freq_table = cpufreq_cdev->freq_table;
unsigned long level;
for (level = 1; level <= cpufreq_cdev->max_level; level++)
if (freq > freq_table[level].frequency)
break;
return level - 1;
}
/**
* cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
* @nb: struct notifier_block * with callback info.
@@ -171,6 +151,27 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
return NOTIFY_OK;
}
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
/**
* get_level: Find the level for a particular frequency
* @cpufreq_cdev: cpufreq_cdev for which the property is required
* @freq: Frequency
*
* Return: level corresponding to the frequency.
*/
static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
unsigned int freq)
{
struct freq_table *freq_table = cpufreq_cdev->freq_table;
unsigned long level;
for (level = 1; level <= cpufreq_cdev->max_level; level++)
if (freq > freq_table[level].frequency)
break;
return level - 1;
}
/**
* update_freq_table() - Update the freq table with power numbers
* @cpufreq_cdev: the cpufreq cooling device in which to update the table
@@ -319,80 +320,6 @@ static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
}
/* cpufreq cooling device callback functions are defined below */
/**
* cpufreq_get_max_state - callback function to get the max cooling state.
* @cdev: thermal cooling device pointer.
* @state: fill this variable with the max cooling state.
*
* Callback for the thermal cooling device to return the cpufreq
* max cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
unsigned long *state)
{
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
*state = cpufreq_cdev->max_level;
return 0;
}
/**
* cpufreq_get_cur_state - callback function to get the current cooling state.
* @cdev: thermal cooling device pointer.
* @state: fill this variable with the current cooling state.
*
* Callback for the thermal cooling device to return the cpufreq
* current cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
unsigned long *state)
{
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
*state = cpufreq_cdev->cpufreq_state;
return 0;
}
/**
* cpufreq_set_cur_state - callback function to set the current cooling state.
* @cdev: thermal cooling device pointer.
* @state: set this variable to the current cooling state.
*
* Callback for the thermal cooling device to change the cpufreq
* current cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
unsigned long state)
{
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
unsigned int clip_freq;
/* Request state should be less than max_level */
if (WARN_ON(state > cpufreq_cdev->max_level))
return -EINVAL;
/* Check if the old cooling action is same as new cooling action */
if (cpufreq_cdev->cpufreq_state == state)
return 0;
clip_freq = cpufreq_cdev->freq_table[state].frequency;
cpufreq_cdev->cpufreq_state = state;
cpufreq_cdev->clipped_freq = clip_freq;
cpufreq_update_policy(cpufreq_cdev->policy->cpu);
return 0;
}
/**
* cpufreq_get_requested_power() - get the current power
* @cdev: &thermal_cooling_device pointer
@@ -536,22 +463,88 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev,
power);
return 0;
}
#endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */
/* cpufreq cooling device callback functions are defined below */
/**
* cpufreq_get_max_state - callback function to get the max cooling state.
* @cdev: thermal cooling device pointer.
* @state: fill this variable with the max cooling state.
*
* Callback for the thermal cooling device to return the cpufreq
* max cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
unsigned long *state)
{
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
*state = cpufreq_cdev->max_level;
return 0;
}
/**
* cpufreq_get_cur_state - callback function to get the current cooling state.
* @cdev: thermal cooling device pointer.
* @state: fill this variable with the current cooling state.
*
* Callback for the thermal cooling device to return the cpufreq
* current cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
unsigned long *state)
{
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
*state = cpufreq_cdev->cpufreq_state;
return 0;
}
/**
* cpufreq_set_cur_state - callback function to set the current cooling state.
* @cdev: thermal cooling device pointer.
* @state: set this variable to the current cooling state.
*
* Callback for the thermal cooling device to change the cpufreq
* current cooling state.
*
* Return: 0 on success, an error code otherwise.
*/
static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
unsigned long state)
{
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
unsigned int clip_freq;
/* Request state should be less than max_level */
if (WARN_ON(state > cpufreq_cdev->max_level))
return -EINVAL;
/* Check if the old cooling action is same as new cooling action */
if (cpufreq_cdev->cpufreq_state == state)
return 0;
clip_freq = cpufreq_cdev->freq_table[state].frequency;
cpufreq_cdev->cpufreq_state = state;
cpufreq_cdev->clipped_freq = clip_freq;
cpufreq_update_policy(cpufreq_cdev->policy->cpu);
return 0;
}
/* Bind cpufreq callbacks to thermal cooling device ops */
static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
.get_max_state = cpufreq_get_max_state,
.get_cur_state = cpufreq_get_cur_state,
.set_cur_state = cpufreq_set_cur_state,
};
static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
.get_max_state = cpufreq_get_max_state,
.get_cur_state = cpufreq_get_cur_state,
.set_cur_state = cpufreq_set_cur_state,
.get_requested_power = cpufreq_get_requested_power,
.state2power = cpufreq_state2power,
.power2state = cpufreq_power2state,
};
/* Notifier for cpufreq policy change */
@@ -659,18 +652,19 @@ __cpufreq_cooling_register(struct device_node *np,
pr_debug("%s: freq:%u KHz\n", __func__, freq);
}
cooling_ops = &cpufreq_cooling_ops;
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
if (capacitance) {
ret = update_freq_table(cpufreq_cdev, capacitance);
if (ret) {
cdev = ERR_PTR(ret);
goto remove_ida;
}
cooling_ops = &cpufreq_power_cooling_ops;
} else {
cooling_ops = &cpufreq_cooling_ops;
cooling_ops->get_requested_power = cpufreq_get_requested_power;
cooling_ops->state2power = cpufreq_state2power;
cooling_ops->power2state = cpufreq_power2state;
}
#endif
cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
cooling_ops);
if (IS_ERR(cdev))